Siemens Simcenter FloEFD 2020.2.0 Free Download

79 views
0
Siemens Simcenter FloEFD 2020

Siemens Simcenter FloEFD 2020

Siemens Simcenter FloEFD 2020 Free Download Latest Version for Windows. It is full offline installer standalone setup of Siemens Simcenter FloEFD 2020 free download with the free for x32/x64 Bit version.

Siemens Simcenter FloEFD 2020 Overview

With this release, a new version numbering was introduced and the switch to a continuous release was completed. From now on, there won’t be major/minor versions released. Instead, new features and physics will be introduced in each scheduled release as they are ready. This enables you to get access to the latest features and physics faster. I should also add that new releases may contain bug fixes, new features and physics and improvements of existing features and physics as well.

The new releases are scheduled every 3 months – in other words, middle of the month in March, June, September, and December. So keep your eyes open for the next releases to come.

Now let’s take a look at the new functionality in Siemens Simcenter FloEFD 2020:

Fan Derating

Fans are often set to run below their maximum capacity, to reduce noise and increase their lifetime, but still achieve thermal cooling requirements. Fans are run under their maximum capacity by reducing the operating RPM. This has the effect of derating (reducing) the fan curve and is simulated in Simcenter FLOEFD by using the Derating factor.

Fan derating.pngThe definition of the fan derating in the fan boundary condition via the fan derating factor.

Siemens Simcenter FloEFD 2019
Logical Expressions in Formula Dependency

Boundary conditions can now be dependent on coordinates, time and monitor parameters such as goals. With the newest release, it is now possible to define sophisticated dependencies using conditional and Boolean expressions such as IF, AND, OR, XOR, NOT, > (more than), < (less than), = (equal two). For example, you can easily set a value of a heat source dependent on two different temperature sensors (defined as temperature goals) so that the dissipated power is downgraded depending on the temperature at either one or another sensor.

Logical expressions.pngThe definition of logical expressions in a boundary condition value specified as a formula dependency.

Altitude Definition

Atmospheric pressure and temperature can be defined by setting the altitude of the object. By using the altitude, it is now much easier to conduct what-if or optimization analysis.

Altitude.pngAltitude definition in the General Settings and the use in an aero heated projectile case at high altitude and Mach number.

Additional Rays for Radiation Sources

You can now use additional rays launched from a radiation source (for Monte Carlo radiation only, requires the LED module). This allows for better resolution of radiation or light locally without significantly increasing the total number of rays for the overall analysis; therefore, saving calculation time. In addition, radiation freezing can be enabled automatically.

You May Also Like Latest Post Global mapper

Siemens Simcenter FloEFD 2020.2.0 v5054 Standalone x64

Siemens Simcenter FloEFD 2020.2.0 v5054 for Solid Edge x64
Siemens Simcenter FloEFD 2020.2.2 v5244 for Siemens NX x64
Siemens Simcenter FloEFD 2020.2.0 v5054 for Creo x64
Siemens Simcenter FloEFD 2020.2.0 v5054 for CATIA V5 x64

Your email address will not be published. Required fields are marked *